Perbandingan Preloading dan Coloading Cairan Kristaloid Ringer Laktat terhadap Tekanan Darah pada Pasien Spinal Anestesi di RS Roemani Muhammadiyah Semarang
DOI:
https://doi.org/10.57213/jrikuf.v3i3.696Keywords:
Preloading, Coloading, Lactated-Ringer, Blood-Pressure, Spinal-AnesthesiaAbstract
Spinal anesthesia is commonly used in surgical procedures but often leads to hypotension due to sympathetic blockade, which can seriously affect the patient's hemodynamic stability. To prevent this, the administration of lactated Ringer crystalloid fluid using preloading (before anesthesia) and coloading (during anesthesia) methods is widely implemented. This study aimed to compare the effects of preloading and coloading on blood pressure stability in patients undergoing spinal anesthesia at Roemani Muhammadiyah Semarang Hospital. A quantitative research method with a comparative observational design and cross-sectional approach was used, involving 40 patients divided equally into preloading and coloading groups. Blood pressure was measured before and after fluid administration, and data were analyzed using paired t-test and independent t-test. Results showed significant changes in blood pressure in both groups (p=0.000; p<0.05). Furthermore, the independent t-test indicated a significant difference between the two methods (p=0.019; p<0.05), with preloading proving more effective in maintaining blood pressure stability than coloading. In conclusion, there is a significant comparison between preloading and coloading of lactated Ringer crystalloid fluid on blood pressure in spinal anesthesia patients, with preloading showing a superior stabilizing effect on blood pressure.
References
Andriyan, A. F., Novera, I., & Insani, E. (2024). Preloading pre spinal anestesi mempengaruhi tekanan sistolik dan diastolik pasien. Jurnal Keperawatan, 17(2), 351–352.
Ansyori, & Rihiantoro, T. (n.d.). Preloading dan coloading cairan Ringer laktat dalam mencegah hipotensi pada anestesi spinal. Jurnal Keperawatan.
Azizah, R. N. (2016). Efek pemberian cairan koloid dan kristaloid terhadap tekanan darah. Berkala Kedokteran, 12(1), 19.
Chekol, W. B., Melesse, D. Y., & Mersha, A. T. (2021). Incidence and factors associated with hypotension in emergency patients that underwent cesarean section with spinal anaesthesia: Prospective observational study. International Journal of Surgery Open, 35, 100410.
Chusnah, L., Eka, Z., & Seoemah, N. (2021). Hubungan usia dengan kejadian hipotensi pada pasien dengan spinal anestesi di Instalasi Bedah Sentral RSUD Bangil. Universitas Bina Sehat PPNI.
Fikran, Z., Tavianto, D., & Maskoen, T. T. (2016). Perbandingan efek pemberian cairan kristaloid sebelum tindakan anestesi spinal (preload) dan sesaat setelah anestesi spinal (coload) terhadap kejadian hipotensi maternal pada seksio sesarea. Jurnal Anestesi Perioperatif.
Hahn, R. G. (2018). Clinical fluid therapy in the perioperative setting. Springer.
Kaufner, L., Karekla, A., Henkelmann, A., Welfle, S., Weizsäcker, K. V., Hellmeyer, L., & Heymann, C. V. (2019). Crystalloid coloading vs. colloid coloading in elective caesarean section: Postspinal hypotension and vasopressor consumption, a prospective, observational clinical trial. Journal of Anesthesia.
Notoatmodjo, S. (2018). Metodologi penelitian kesehatan. Rineka Cipta.
Puspitasari, I. A., Hendarsih, S., & Delima, E. R. (2019). Faktor-faktor yang mempengaruhi kejadian hipotensi pada pasien dengan spinal anestesi di RSUP Dr. Soeradji Tirtonegoro. Poltekkes Kemenkes Yogyakarta. Diambil kembali dari http://eprints.poltekkesjogja.ac.id/3571/
Soepraptomo, R. (2020). Laporan kasus regional anestesi subarachnoid block pada wanita 34 tahun G2P1A0 hamil preterm, pre eklamsia berat, ketuban pecah dini 18 jam, pro SCTP dengan status fisik ASA II E. Jurnal Komplikasi Anestesi, 7(2), 37–40. https://doi.org/10.22146/jka.v7i2.7455
Supriyatin, T., Siwi, A. S., & Rahmawati, A. N. (2022). Pencapaian Bromage dan Aldrete score pada tindakan anestesi di Instalasi Bedah Sentral (IBS) RSUD Ajibarang. Seminar Nasional Penelitian dan Pengabdian kepada Masyarakat (SNPPKM).
Taono, A. S., Nova, H. R., & Rahmawati, A. N. (2023). Pemberian co-loading cairan kristaloid terhadap perubahan tekanan darah pada pasien spinal anestesi di Rumah Sakit Jatiwinangun Purwokerto. Jurnal Inovasi Global, 2(9), 1378–1388. https://doi.org/10.58344/jig.v2i9.177
Trisandi, M. M., Rohmah, A. N., & Rosidah, I. (2024). Pengaruh pemberian preloading cairan terhadap tekanan darah pada pasien spinal anestesi di RSUD Wonosari Yogyakarta. Jurnal Borneo Cendekia, 8(1), 20–29.
Zulfakhrizal, Sumarni, T., & Haniyah, S. (2023). Hubungan usia dengan kejadian hipotensi pada pasien pasca spinal anestesi di Kamar Operasi Rumah Sakit Umum Tgk. Chik Ditiro Sigli Kabupaten Pidie Aceh. Jurnal Kesehatan, Kebidanan, dan Keperawatan, 16(2), 175–177. https://doi.org/10.35960/vm.v16i2.908
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Jurnal Riset Ilmu Kesehatan Umum dan Farmasi (JRIKUF)

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.